Facade 5050 SG System Glazing Configuration
- Well-insulated profiles
- Framework profiles Rectangular, profile depth 60-180 mm
- Opening windows with hidden sash
- Doors Hinge type and sliding doors can be easily connected
- Classified According to applicable EN standards
Available profiles
Vertical profiles (pdf) (dwg)
Horizontal profiles (pdf) (dwg)
Drawing texts
The texts are intended to help the specifiers to define which systems, fittings, glazing units, surface treatment alternatives and functions are required. The licensed fabricators later use them during the production of the finished products.
Download the text as .dwg
Download the text as .pdf
U values for glass facades
Formula for calculating the total U value of a facade, taking into account the glazing unit, the share of profiles and an edge zone effect linear factor.
Ufacade = ( Ag * Ug + Af * Uf + Ig * ψg ) / ( Ag + Af )
The links below present tables with the total U value of a facade for different glazing units and distance strips. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9 and the calculations standard for curtain walls EN 13947:2006.
U value for a facade with a double glazing unit <BR>and an aluminium spacer
|
|
|
|
|
|
|
|
|
|
Share of profiles |
U value of glass Ug W/m2K (middle point)
Aluminium spacer |
|
|
1,0 |
1,1 |
1,2 |
1,3 |
1,4 |
1,5 |
1,6 |
|
5 % |
1,3 |
1,4 |
1,5 |
1,5 |
1,6 |
1,7 |
1,8 |
|
10 % |
1,5 |
1,6 |
1,7 |
1,8 |
1,9 |
2,0 |
2,1 |
|
15 % |
1,8 |
1,9 |
1,9 |
2,0 |
2,1 |
2,2 |
2,3 |
|
20 % |
2,0 |
2,1 |
2,2 |
2,2 |
2,3 |
2,4 |
2,5 |
|
For more information please contact our Architect Support
|
U value for a facade with a double glazing unit <BR>and a warm edge spacer
|
|
|
|
|
|
|
|
|
|
Share of profiles |
U value of glass Ug W/m2K (middle point)
Warm edge spacer |
|
|
1,0 |
1,1 |
1,2 |
1,3 |
1,4 |
1,5 |
1,6 |
|
5 % |
1,2 |
1,3 |
1,4 |
1,5 |
1,6 |
1,7 |
1,8 |
|
10 % |
1,4 |
1,5 |
1,5 |
1,6 |
1,7 |
1,8 |
1,9 |
|
15 % |
1,5 |
1,6 |
1,7 |
1,8 |
1,9 |
2,0 |
2,1 |
|
20 % |
1,7 |
1,8 |
1,9 |
2,0 |
2,0 |
2,1 |
2,2 |
|
For more information please contact ourArchitect Support
|
U values for infill panels
Only Vaku Paneel can be used as infill panels in the 5050 SG facade system. The middle point U values for infill panels are presented below. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9.
|
|
|
|
|
U value of infill panel Up W/m2K (middle point)
|
Vaku Paneel distance strip
|
16
|
18
|
24
|
28 |
Panel thickness in mm
|
26-28 |
26-28 |
31-35 |
31-35 |
U value of infill panel in W/m2K
|
0,29 |
0,28 |
0,18 |
0,16 |
For more information please contact our Architect Support |
|
Surface layer: |
|
Glass, aluminium sheet and steel sheet are the standard materials |
|
Colours: |
|
For glass and sheet metal according to RAL, NCS or DB (Akso Nobel) |
|
Sizes: |
|
Min. 350x350 mm, Max. 2400x4500 mm |
|
Noise reduction: |
|
Rw 42 dB for a glass and 3 mm sheet metal combination |
|
Fire: |
|
Vaku Paneel is classified as non-flammable |
|
U value: |
|
From 0.29 to 0,29- 0,16 W/m2 K |
Glazing
Unprotected glazed surfaces, which are located so that persons can reach them and shall be designed to limit the risk of injury. Such glazed surfaces shall be dimensioned so as to withstand the dynamic influence of a person. Applicable standards and requirements should be taken into account.
Glass thickness 26-41 mm (double glazing units) or 46-51 mm (tripple glazing units).
The illustration shows the different functional dimensions commonly used by the window industry and established by the MTK. The gaskets are made of EPDM rubber and are available in several versions.
Opening units
The facade system can be easily complemented with 4074 outward opening windows and 2086 doors.
The 4074 window system is suitable for integrating in the facade system. The outward opening windows can be provided with fittings for either horizontal or vertical projection function.
The 2086 door system includes inward and outward opening single or double-leaf doors.
4074 facade windows
|
- |
Profile depth 84 mm |
- |
Insulated aluminium profiles |
- |
Rebate for double glazing units |
|
2086 SX doors
|
- |
Profile depth 86 mm |
- |
Insulated aluminium profiles |
- |
Inward or outward opening |
- |
Single- or double-leaf doors |
- |
Rebate for double and triple glazing units |
|