Sapa Facade 4150 - Insulated

The 4150 facade system consists of 50 mm wide insulated aluminium profiles. The design of the inside gasket and the thermal break optimises the insulation of the profiles.

The profiles are available in a number of different depths. They are designed so as to ensure stability under the dimensioning loads and are joined together with hidden joints. The system can be easily complemented with opening units. The U value of a facade must be calculated for the entire facade.

Facade 4150 Configuration

  • Well-insulated profiles
  • Several types of mullion and transom profiles. Rectangular (profile depth 35-300 mm), I- and T-shaped profiles give a lot of freedom in interior design
  • Wide range of decorative caps for exterior design
  • Four window systems, both inward and outward opening
  • Doors Hinge type and sliding doors can be easily integrated
  • Fire protection Available in fire resistance class E 30, EI 15 or EI 30
  • Classified According to applicable EN standards

Elevations & Details

A4150-1028 1011161777172737374
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1029 110163
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1030 1101116177
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1024 10141721222331323334414243
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1025 1111316234
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1026 10168
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1027 1101635051
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1018 110111213131415162212234566162636471727374818284
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1019 1101112131417234566162636471727374818284
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1020 110151623456
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1021 1101112131416181922122345661626364717273748182849
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1022 110111213141718182345661626364717273748182849
Save this elevation as: dwg / dxf
Click on number to view the details
A4150-1023 110161919359
Save this elevation as: dwg / dxf
Click on number to view the details

Available profiles

Mullion & transom profiles (pdf) (dwg)
Mullion & transom profiles, I- and T-shaped profiles (pdf) (dwg)
Mullion & transom profiles, corner and faceting profiles (pdf) (dwg)
Dividing profiles (pdf) (dwg)
Decorative profiles (pdf) (dwg)
Decorative profiles (pdf) (dwg)

Drawing texts

The texts are intended to help the specifiers to define which systems, fittings, glazing units, surface treatment alternatives and functions are required. The licensed fabricators will later use them during the production of the finished products.

Download the text as .dwg
Download the text as .pdf

Dodając ten tekst w swoich dokumentach przetargowych  pomagasz zaprojektować budynki przyszłości.

Rozwiązanie systemowe wykorzystuje materiał pochodzący z recyclingu w następujących obszarach:

  • Aluminium uzyskane w co najmniej 75% z recyklingu (EoL) e.g. AW 6060T66

For aluminium with EoL recovery, material that has already been installed in and removed from a building, is recycled again. The minimum 75 percent proportion of this post-consumer material (>75% EoL material) must be verified by means of an independent certification.

U values for glass facades

Formula for calculating the total U value of a facade, taking into account the glazing unit, the share of profiles and edge zone, affect the linear factor.

Ufasad = ( Ag * Ug + Af * Uf + Ig * ψg )  /  ( Ag + Af )

The links below present tables with the total U value of a facade for different glazing units and spacer. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9 and the calculations standard for curtain walls EN 13947:2006.

U value for a facade with a double glazing unit <BR> and an aluminium spacer

Share of profiles
U value of glass Ug W/m2K (middle point)

Aluminium spacer
1,0
1,1
1,2
1,3
1,4
1,5
1,6
5 %
1,2 1,3 1,4 1,5 1,6 1,7 1,8
10 %
1,5 1,6 1,7 1,8 1,9 2,0 2,1
15 %
1,8 1,9 2,0 2,0 2,1 2,2 2,3
20 %
2,0 2,1 2,2 2,3 2,4 2,4 2,5
For more information please contact our Architect Support


U value for a facade with a double glazing unit <BR>and a warm edge spacer

Share of profiles
U value of glass Ug W/m2K (middle point)

Warm edge spacer
1,0
1,1
1,2
1,3
1,4
1,5
1,6
5 %
1,2 1,3 1,4 1,4 1,5 1,6 1,7
10 %
1,3 1,4 1,5 1,5 1,6 1,7 1,8
15 %
1,4 1,5 1,6 1,7 1,8 1,8 1,9
20 %
1,5 1,6 1,7 1,8 1,9 1,9 2,0
For more information please contact our Architect Support


U value for a facade with a triple glazing unit <BR>and an aluminium spacer

Share of profiles
U value of glass Ug W/m2K (middle point)

Aluminium spacer
0,4
0,5
0,6
0,7
0,8
0,9
1,0
5 %
0,6 0,7 0,8 0,9 1,0 1,1 1,2
10 %
0,9 1,0 1,1 1,2 1,3 1,4 1,5
15 %
1,1 1,2 1,3 1,4 1,5 1,6 1,7
20 %
1,4 1,5 1,5 1,6 1,7 1,8 1,9
For more information please contact our Architect Support


U value for a facade with a triple glazing unit <BR>and a warm edge spacer

Share of profiles
U value of glass Ug W/m2K (middle point)

Warm edge spacer
0,4
0,5
0,6
0,7
0,8
0,9
1,0
5 %
0,5 0,6 0,7 0,8 0,9 1,0 1,1
10 %
0,6 0,7 0,8 0,9 1,0 1,1 1,2
15 %
0,7 0,8 0,9 1,0 1,1 1,1 1,2
20 %
0,8 0,9 1,0 1,1 1,1 1,2 1,3
For more information please contact our Architect Support


U values for infill panels

The links below present tables with the middle point U value for different infill panels. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9.

Infill panel




U value of infill panel in Up W/m2K (middle point)
U value of infill panel in
W/m2K
0,65
0,48
0,38
0,31
0,27
0,21
Profile depth in mm
60 80 100 120 140 180
For more information please contact ourArchitect Support


Window dimensions

Frame outside dimensions for 4074 facade windows (.pdf).
For other window dimensions see Windows in the left hand menu.

For more information please contact our Architect Support.

Dimensioning

Rough calculation of facade profiles
See tables below in PDF format.

Facade mullion on 2 supports
Facade mullion on 3 supports
Facade mullion on at least 4 supports
Dimensioning with regard to the weight of glass

For help with dimensioning please contact our Architect Support.

Glazing

Unprotected glazed surfaces that can be reached by persons shall be designed to limit the risk of injury. Such glazed surfaces shall be dimensioned so as to withstand the dynamic influence of a person. Applicable standards and requirements should be taken into account.

Glass thickness 23-48 mm


The illustration shows the different functional dimensions commonly used by the window industry and established by the MTK. The gaskets are made of EPDM rubber and are available in several versions.

Opening units

The window frames are specially adapted to the glass rebate of the facade system for simple installation. The windows in the 1086 window system are available as tilt and turn, bottom- hung, top-hung and side-hung, inward opening units.

The 2086 door system includes inward and outward opening single or double leaf doors with frame profiles that are specially adapted to the glass rebate of the facade system for simple installation.

1086 windows, inward opening

- Profile depth 86 mm
- Insulated aluminium profiles
- Side, bottom or top-hung
- Tilt and turn
- Rebate for double and triple glazing units

1086 windows, outward opening

- Profile depth 86 mm
- Insulated aluminium profiles
- Side, bottom or top-hung
- Rebate for double and triple glazing units
   
   

1086 block windows, inward opening



- Profile depth 86 mm
- Insulated aluminium profiles
- Tilt and turn
- Rebate for double glazing units
- Fals för 2-glas

4074 facade windows, outward opening

- Profile depth 88 mm
- Insulated aluminium profiles
- Top hung projection
- Bottom hung projection
- Rebate for double glazing units
   
   

2086 SX doors

- Profile depth 86 mm
- Insulated aluminium profiles
- Inward or outward opening
- Single or double leaf doors
- Rebate for double and triple glazing units
   
   

Facade additions

Opinions differ among designers on how the outside joints of a glass facade should be shaped. We have two different decorative profile systems: Add and Expressive

Add, offers a design concept with its visible fastening elements and characteristic groove. The add cap is also able to support solar shading elements, lightning conductors, down pipes, rain gutters, signboards and lighting.

Expressive, gives the designer more freedom in the play of light and shadow on the facade. It is also possible to design one's own decorative profiles if needed.

Add, decorative profiles

Add 42693 basic decorative cap with mitred connection. Add 42693 basic decorative cap complemented with coloured profile. Add 42693 basic decorative cap with large screw mounting.

Add, support system

   
Add 42693 basic decorative cap with down pipe   Add 42693 basic decorative cap with lightning conductor cable   Add 42693 basic decorative cap with connection for solar shading elements
         

Expressive, decorative profiles

Expressive 42695 flanged cap in horizontal arrangement combined with 42227 profile in vertical arrangement Expressive 68827 decorative cap in horizontal arrangement combined with 68823 wing profile in vertical arrangement Expressive 42695 flanged cap in horizontal and vertical arrangement

Expressive 68819 T-cap in horizontal and vertical arrangement Expressive 68827 U-cap in horizontal and vertical arrangement Expressive 42813 pyramid cap in horizontal arrangement combined with 42811 cap in vertical arrangement

References 4150

Product overview

The 4150 facade system consists of 50 mm wide insulated aluminium profiles. The design of the inside gasket and the thermal break optimises the insulation of the profiles.

The profiles are available in a number of different depths. They are designed so as to ensure stability under the dimensioning loads and are joined together with hidden joints. The system can be easily complemented with opening units. The U value of a facade must be calculated for the entire facade.

SAPA BUILDING SYSTEMS -
Please choose your language